Manufacturer number: MDO34-3-BW-100
€5,460.00
Article number: | MDO34 3-BW-100 |
---|---|
Bandwidth (MHz): | 100 |
Counter: | Yes |
DVM: | Yes (free after product registration) |
Dimensions (L x W x H) (mm): | 148.6 x 370 x 252 |
Function generator: | Optional: AFG |
Interfaces: | USB, LAN |
Model: | MDO34-3-BW-100 |
Number of channels: | 4 |
Samplerate: | 5 GSa/s |
Screen size: | 29.5 cm |
Screen type: | 1920 x 1080, HD touchscreen |
Signal acquisition rate: | 280,000 wfms/s |
Special features: | Bandwidth upgrade up to 1GHz 1GHz Spectrum Analyzer |
Storage depth: | 10 MPts |
Triggertypes: | Edge, Sequence (B-trigger), Pulse Width, Timeout, Runt, Logic, Setup and Hold, Rise/Fall Time, Video Optional: Parallel |
Vertical resolution: | 8-bit |
Warranty (years): | 1 |
Weight (kg): | 5.31 |
Compact design, powerful signal acquisition and efficient signal analysis: With the oscilloscope MDO34 you get extensive analysis tools for fast design characterization and identification of signal anomalies. With over 125 trigger combinations, you can quickly trace the cause of signal errors. The large recording length of up to 10 million points enables extensive recording of all signal events.
For mixed signal applications, the MDO34 offers 16 digital channels (with an optional logic analyzer) in addition to the two analog channels, thus enabling the simultaneous display of analog and digital signals. In addition, the MDO34 has an integrated, hardware-based spectrum analyzer with a frequency range from 9 kHz to 1 or 3 GHz, which supports signal analysis for IoT applications and other common radio standards.
The MDO34 oscilloscope offers an integrated 4-digit digital voltmeter (DVM) and a 5-digit trigger frequency counter for the precise display of the frequency of the executed trigger event. Each of the analog inputs can serve as a source for the voltmeter. The same probes are used for this as for the use of the oscilloscope. The MDO Series 3 also has an optional, integrated arbitrary function generator (AFG), which is ideally suited for the simulation of sensor signals or for generating noise signals when carrying out limit value tests. The signal generator enables the output of predefined signals up to 50 MHz and offers 128,000-point recording for loading signals from an internally stored file, from a USB storage device or an external PC. The optional performance analysis package enables fast and reproducible analyzes of performance quality, harmonics, switching loss, modulation, ripple as well as efficiency, amplitudes or time measurements.
The Series 3 MDO optionally offers a comprehensive set of reliable tools for common serial buses such as I2C, SPI, RS-232/422/485 / UART, USB2.0, CAN, CAN FD, LIN, FlexRay, MIL-STD-1553 , ARINC429 and I2S / LJ / RJ / TDM. With serial protocol triggering you can trigger on certain packet contents, e.g. B. package start, specific address, unique identifier or error. The bus signal is time-correlated to all other signals displayed, so that the timing relationships between the different parts of the tested system are easy to determine. Decoding tables provide a tabular view of all decoded packets from one acquisition.
In the new issue of “dataTec unboxed” we present the new InfiniiVision HD3 oscilloscopes from Keysight with 14-bit ADC.
Embedded systems applications are growing rapidly in the automotive industry. Many vehicle designs use CAN, LIN or FlexR...
Engineers primarily use oscilloscopes to debug and characterize various automotive serial buses. These include the contr...
It is widely expected that wide bandgap (WBG) devices—using silicon carbide (SiC) and gallium nitride (GaN) transistors—...
Navigating through the range of available specifications, options and capabilities can be challenging. There are a lot o...
As data rates continue to increase in today’s state-of-the-art high-speed digital designs, timing budgets are decreasing...
Current probes extend the application abilities of oscilloscopes beyond voltage measurement. Basically, current clamps m...
The market offers a wide choice of oscilloscopes for sale. This makes it difficult to decide which oscilloscope to buy a...
Your oscilloscope trigger determines the precise moment in time your instrument captures critical events of interest. Tr...
Oscilloscope users consistently rate bandwidth, sample rate and memory depth as the three most important specifications....
Getting EMI emissions under control is one of those tasks that R&D engineers do not enjoy doing . EMI must often be ...