Manufacturer number: P01196773
| Analogue segment display: | Yes |
|---|---|
| Article number: | P01196773 |
| Backlight: | Yes |
| Basic precision: | AC 1.2 % / DC 0.2 % |
| Capacity measuring range: | 6 nF - 60 mF |
| Current measuring range AC/DC: | 6A - 10A / 6A - 10A |
| Data memory / logger: | No / No |
| Dimensions (L x W x H) (mm): | 190 x 90 x 45 |
| Diode test / continuity test: | Yes / Yes |
| Display Hold / Auto-Hold: | Yes / Yes |
| Display resolution: | 12,000 |
| Electrical safety: | CAT III 600 V |
| Frequency measuring range: | 600 Hz - 50 kHz |
| Min. / Max. Recording: | No / No |
| Model: | CA5273 |
| Number of positions: | 3.75 |
| Resistance measuring range: | 600 Ω - 60 MΩ |
| Temperature measurement ( PT100 / Type K / Type J): | Type K |
| True effective measurement TRMS: | Yes |
| Voltage measuring range AC/DC: | 600 mV - 1000 V / 60 mV - 1000 V |
| Warranty (years): | 3 |
| Weight (kg): | 0.4 |
The CA 5273 is particularly ergonomic and compact. The protection type of the handy device is IP54. The very easy-to-read double digital display with 6000 digits is illuminated and has a bar graph with 61 + 2 segments, 2 remanence modes and switchable to central zero.
The safety of the CA 5273 multimeter leaves nothing to be desired and corresponds to measurement category 600 V CAT IV.
The CA 5273 were developed by CHAUVIN ARNOUX, are built in France