Our electromagnetic environment is heavily burdened due to the multitude of transmitters and sources of interference pre...
Automated test and measurement systems that are fully connected with instrumentation and test data can significantly inc...
Temperature is one of the most common risk factors in industry. Overheating can disrupt processes, reduce quality or cau...
Electric vehicles are the future - but what happens to the batteries when they can no longer be used in cars? Efficient ...
Manufacturer number: MSO68B
Article number: | MSO68B |
---|---|
Counter: | Yes (free after product registration) |
DVM: | Yes (free after product registration) |
Dimensions (L x W x H) (mm): | 204 x 454 x 309 |
Function generator: | optional AFG 50MHz |
Interfaces: | USB, LAN |
Model: | MSO68B |
Number of channels: | 8 |
Samplerate: | 50 GSa/s |
Screen size: | 39.6 cm |
Screen type: | 1920 x 1080, HD touchscreen |
Signal acquisition rate: | 500,000 wfms/s |
Special features: | FlexChannel technology - up to 64 digital channels |
Storage depth: | 125 MPts |
Triggertypes: | Edge, Pulse Width, Timeout, Runt, Window, Logic, Setup&Hold, Rise/Fall Time Sequence, Visual, Parallel Optional: Video, RF vs Time |
Vertical resolution: | 12-bit |
Weight (kg): | 13.52 |
Characterize and debug cutting edge designs with greater confidence.
More bandwidth. More channels. Less noise.
Note: basic device. Please select the optimal variant for your application under " Other products ".
Troubleshooting and validation of high-speed designs, mask testing, serial protocol triggering and analysis, advanced jitter analysis or compliance testing for serial buses: with the 6B series mixed signal oscilloscope you are equipped for current and future measurement applications - with one expandable bandwidth from 1 to 10 GHz, versatile and precise measurement functions and a sampling rate of 50 GSa / s.
The Tektronix MSO68B oscilloscope with FlexChannel technology optimizes system visibility for complex signals in verification and debugging processes. The 8 FlexChannel inputs each offer an analog signal input or eight digital logic inputs (with optional logic probe). This means that up to 64 digital channels can be implemented flexibly . An analog signal can be displayed as a curve or as a frequency spectrum - both views can also be displayed simultaneously. This makes oscilloscope-based analysis in the frequency domain as easy as with a spectrum analyzer, while maintaining the time reference to other signal events.
The digital channels have the same high real-time sampling rate of up to 50 GSa / s for high-precision timing resolutions and the same large recording length (up to 1 G points) for long-term acquisition as the analog channels . The particularly large 15.6-inch color display with touch function and full HD resolution enables you to clearly and simultaneously display many signals and analyzes.
The MSO68 oscilloscope offers an integrated 4-digit digital voltmeter (DVM) and an 8-digit frequency counter. Any of the analog inputs can serve as a source for the voltmeter. The same probes are used for this as for oscilloscope use. The MSO 6 B series also has an optional, integrated arbitrary function generator (AFG) , which is ideally suited for simulating sensor signals or for generating noise signals when performing limit value tests. The signal generator enables the output of predefined signals up to 50 MHz and offers a 128,000 point recording for loading signals from an internally stored file or a USB storage device. The optional power analysis package enables quick and reproducible analyzes of, among other things, power quality, harmonics, switching loss, modulation, ripple as well as efficiency, amplitude or time measurements.
The mixed signal oscilloscope of the 6 B series optionally offers a comprehensive set of reliable tools for common serial buses such as I2C, SPI, RS-232/422/485 / UART, CAN, CAN FD, LIN, FlexRay, SENT, PSI-5, 100BASE-T, USB LS / FS / HS, Ethernet 100 / 1000BASE-T1 and MIL-STD-1553, Spacewire and ARINC 429 . Parallel buses are also supported by the MSO68 (by default). With the serial protocol triggering you can trigger on certain packet contents, e.g. B. Start of package, specific address, unique identifier or error. The bus signal is time-correlated with all other displayed signals, so that the timing relationships between the various parts of the system under test are easy to determine. Decode Tables provide a tabular view of all decoded packets from an acquisition.
In the new issue of “dataTec unboxed” we present the new InfiniiVision HD3 oscilloscopes from Keysight with 14-bit ADC.
Embedded systems applications are growing rapidly in the automotive industry. Many vehicle designs use CAN, LIN or FlexR...
Engineers primarily use oscilloscopes to debug and characterize various automotive serial buses. These include the contr...
It is widely expected that wide bandgap (WBG) devices—using silicon carbide (SiC) and gallium nitride (GaN) transistors—...
Navigating through the range of available specifications, options and capabilities can be challenging. There are a lot o...
As data rates continue to increase in today’s state-of-the-art high-speed digital designs, timing budgets are decreasing...
Current probes extend the application abilities of oscilloscopes beyond voltage measurement. Basically, current clamps m...
The market offers a wide choice of oscilloscopes for sale. This makes it difficult to decide which oscilloscope to buy a...
Your oscilloscope trigger determines the precise moment in time your instrument captures critical events of interest. Tr...
Oscilloscope users consistently rate bandwidth, sample rate and memory depth as the three most important specifications....
Getting EMI emissions under control is one of those tasks that R&D engineers do not enjoy doing . EMI must often be ...