The P5205A differential high voltage probe can be used with any oscilloscope with a TekProbe interface. The probe enables the safe measurement of floating circuits when the oscilloscope is earthed. The P5205A active differential probe converts floating signals into ground-referenced low-voltage signals that are displayed safely and easily on the ground-referenced oscilloscope. The attenuation factor can be switched from 50x to 500x on the probe.
Application areas:
- Ground-free measurements
- Design of switching power supplies
- Design of motor drives
- Electronic load control
- CRT display design
- Evaluation of power components
Features and highlights:
- Bandwidth: 100 MHz
- Attenuation factor: 50x or 500x, switchable
- Maximum differential input voltage: ±1300 V at 500x and ±130 V at 50x
- Maximum common mode voltage: ±1300 V
- Common mode rejection: >80 dB (DC), >60 dB (100 kHz), >40 d (3.2 MHz), >30 dB (50 MHz), typ.
- Maximum input voltage referred to ground: 1000 V CAT II
- Differential input impedance: 10 MΩ / 2 pF
- Input impedance: 5 MΩ / 4 pF
- Overvoltage indicator
- Switchable bandwidth limiter
- Connection: TekProbe interface
- Cable length: 1.8 m
Please note: Special items / stock sales are in their original packaging and unused. All special items are guaranteed for 1 year. Subject to prior sale. The configuration of a special item cannot be changed. The calibration of a special item may no longer be up to date. If you would like an up-to-date calibration, please contact our experts.
Give us a call, we will be happy to consult you personally:
+49 (0)7121 / 51 50 50