Our electromagnetic environment is heavily burdened due to the multitude of transmitters and sources of interference pre...
Automated test and measurement systems that are fully connected with instrumentation and test data can significantly inc...
Temperature is one of the most common risk factors in industry. Overheating can disrupt processes, reduce quality or cau...
Electric vehicles are the future - but what happens to the batteries when they can no longer be used in cars? Efficient ...
Manufacturer number: CNT-90
AC input: | 100 VAC - 240 VAC, 50 Hz - 400 Hz (Nom.), < 40 W, < 60 W battery operation |
---|---|
Article number: | CNT-90 |
Dimensions (L x W x H) (mm): | 395 x 210 x 90 |
Event Count (Totalize): | 750.000 |
Input impedance: | 1 MΩ parallel 20 pF or 50 Ω |
Interfaces: | USB, LAN |
Measurement functions: | Frequency, period, time range, phase, duty cycle, pulse duration, rise-fall time |
Measurement resolution (gate time): | 1.6 ns |
Measuring range RF (MHz): | 400 |
Measuring resolution: | 12 digits/s |
Messwertstatistik: | current measured value, minimum, maximum, standard deviation |
Min. pulse width: | 100 ps |
Model: | CNT-90 |
Number of channels: | 2 |
Options/Extensions: | Optional: Channel 3 (3 GHz, 8 GHz, 15 GHz, 20 GHz) |
Sensitivity: | 15 mVrms: 200 MHz / 25 mVrms: 200 MHz - 300 MHz / 35 mVrms: 300 MHz - 400 MHz |
Trigger source: | Internal, External, Bus, Manuel |
Warranty (years): | 3 |
Weakening: | Trigger range: x10 / x1 |
Weight (kg): | 2.7 |
The powerful CNT-90 frequency counter from Pendulum Instruments is characterized by its high measuring speed and resolution. It is used as a high-performance analyzer for the high-precision measurement and calibration of frequencies, time intervals or phases. Its speed enables up to 250,000 measurements per second. The measurement resolution for the time domain measurement is up to 100 ps. The CNT-90 displays frequency measurements with 12 digits.
Thanks to the intuitive, menu-driven operation of the CNT-90 via graphic display, you have optimal control over your analyzes. The visual calibration instructions ensure an even more comfortable use of the device. The portable frequency counter is also available with a battery for maximum versatility.
With the modulation domain analyzer software TimeView 2, you can expand your measurement and statistical functions to analyze dynamic signal changes in time or frequency in real time. B. for analyzing hopping frequencies up to 20 GHz, PLL and FPL (phase / frequency locked loop), CW (continuous wave), Doppler pulse or chirp radar signals, digital modulations such as FSK or for measuring frequency stability (Allan deviation ADEV ). Thanks to the integrated FFT and signal display, the input signal can be displayed in both the frequency and time domain.
High performance timer / counter / analyzer: