Manufacturer number: M694C
| All-current sensitive RCDs type B, B+: | No |
|---|---|
| Article number: | M694C |
| Automatic test sequence: | Yes |
| Check residual voltage: | No |
| Counter start-up: | No |
| DIN VDE 0100 / IEC 60364-6: | No |
| DIN VDE 0100-600: | No |
| DIN VDE 0105-100: | No |
| DIN VDE 0113-1 / IEC 60204-1: | No |
| DIN VDE0544-4 / IEC 60974-4: | Yes |
| DIN VDE 0701-0702: | Yes |
| DIN VDE 0751 / IEC62353: | Yes |
| Differential power: | 0.2 - 30.0 mA |
| Dimensions (L x W x H) (mm): | 295 x 145 x 150 |
| EN 50678 (prepared): | Yes |
| EN 50699 (prepared): | Yes |
| Earth conductor 10A: | Yes |
| Earth conductor 25A: | No |
| High voltage test DC: | No |
| Interfaces: | USB |
| Isolation: | 0 - 300 MΩ |
| Measured value memory: | 50000 |
| Mobile: | Yes |
| Model: | Seculife ST PRO IQ |
| Protective earth less than 200mA: | Yes |
| Rotating field direction: | No |
| Selective, SRCDs, PRCDs, type G/R: | PRCDs, PRCD-S, PRCD-K |
| Software included: | IZYTRONIQ |
| Stationary: | No |
| Touch Display: | Yes |
| Voltage drop: | No |
| Weight (kg): | 4 |
| e-Mobility (prepared): | No |
The Gossen Metrawatt SECULIFE ST PRO IQ supports all required measurement and test functions to test the effectiveness of protective measures in medical devices and systems - with both predefined and programmable test sequences that comply with the test standards VDE 0701-0702, IEC / EN 62353 ( VDE 0751) and IEC / EN 60601 are necessary. Equipping the front of the housing and the housing with an antimicrobial effect enables the device to also be used in hygienically sensitive areas (medical technology, pharmaceuticals and food industries).
New, optimally adapted measuring cycles, 4 mm application part sockets and a comprehensive UDI administration ensure faster and more efficient measuring and testing. Data is entered into the tester via the integrated USB connection (keyboard, barcode scanner, RFID reader) or the screen keyboard on the color display. Text object data can also be imported, for example with the help of the IZYTRONIQ software supplied.
The DIN VDE regulations govern the electrotechnical regulations as defined by DGUV V3 (accident prevention regulations f...
Thomas Schleich is an engineer, an expounder of ideas, a free spirit – and a first-class speaker at the dataTec Academy....