Manufacturer number: 34951A
| Weight (kg): | 8.8 |
|---|
The 34951A digital / analog converter module for the Keysight switch and measuring unit 34980A has four electronically calibrated analog channels, which allow an output voltage of ± 16 Vdc or 20 mAdc output current with a resolution of 16 bits. Each of these channels can be individually described with an update rate of 200 kHz with new data. The standard waveforms can be used or you can create your own waveform with over 500,000 points. These points can be dynamically assigned to one or more of these channels and the output voltage then follows point by point.
This D / A function is mainly used to simulate supply and setting variables on a DUT (Device Under Test) or to control a power supply unit via its analog input or to supply the output voltage as an input signal for a control unit.
With the standard 50-pin Dsub connector, normal cables and terminal strips can be contacted.