Manufacturer number: M537H
All-current sensitive RCDs type B, B+: | Yes |
---|---|
Article number: | M537H |
Automatic test sequence: | Yes |
Check residual voltage: | Yes |
Counter start-up: | Yes |
DIN VDE 0100 / IEC 60364-6: | Yes |
Dimensions (L x W x H) (mm): | 265 x 330 x 90 |
Insulation measurement 50V: | Yes |
Insulation measurement 100V: | Yes |
Insulation measurement 250V: | Yes |
Insulation measurement 325V: | Yes |
Insulation measurement 500V: | Yes |
Insulation measurement 1000V: | Yes |
Interfaces: | USB |
Measured value memory: | 50000 |
Mobile: | Yes |
Model: | PROFITEST MXTRA 0105 Set |
Rotating field direction: | Yes |
Selective, SRCDs, PRCDs, type G/R: | Yes |
Software included: | Izytroniq |
Stationary: | No |
Touch Display: | No |
Voltage drop: | Yes |
Warranty (years): | 10 |
Weight (kg): | 2.7 |
e-Mobility (prepared): | Yes |
The Gossen Metrawatt PROFITEST MF XTRA supports you in testing the effectiveness of protective measures on stationary electrical installations in accordance with E-CHECK / DIN VDE 0100-600 / VDE 0413 / VDE 0105-100.
Protective measures in electrical systems are intended to protect human life from accidents involving electricity and thus ensure its integrity. Of course, they should also protect material values from damage caused by electricity. Every electrical installation must be tested with this VDE test device before it is put into operation for the first time and then at regular intervals for the effectiveness of the existing electrical protective measures. Your advantage: low-impedance, insulation, earth resistance, site insulation, loop and network impedance measurement and legally compliant documentation in one test device.
In addition to the installation tester, the PROFITEST MF XTRA 0105 Set M537H also includes the METRAVOLT 12D+L voltage and continuity tester with phase, polarity and rotary field test, the SORTIMO L-BOXX system case with internal divisions for PROFITEST and accessories, and the IZYTRONIQ BUSINESS Professional software Cloud Voucher.
The DIN VDE regulations govern the electrotechnical regulations as defined by DGUV V3 (accident prevention regulations f...
Thomas Schleich is an engineer, an expounder of ideas, a free spirit – and a first-class speaker at the dataTec Academy....