Chauvin Arnoux P01120052A | Clamp current transformer D33N for AC current measurement from 1 to 3,600 A connection cable with 4 mm sockets for connection to a multimeter.
Enclosure diameter 64 x 150 mm
Measuring ranges: 1..3.600 A AC
Gear ratios of the measuring ranges: 3000: 5
Typical accuracy ≤ 1%
Frequency range: 30 Hz ... 5 kHz
AC current output to the measuring device: 5 A AC
Connection on the pliers with 4 mm safety sockets
Suitable for multimeters, oscilloscopes, recorders etc. with 4 mm safety sockets
IEC 1010.2.032, Cat.III, 600 V for industrial applications
Independant Consulting
More than 50 strong brands and exclusive partnerships.
P01120052A | D33N current probe, 4 mm, 3600 A 30 Hz - 5 kHz, I-Out
The clamp-type current transformers of the D series from CHAUVIN-ARNOUX are particularly characterized by their high reliability and exact measurement results.
The D33N current probe measures electrical currents up to 3600 amperes alternating current. The frequency range of the CHAUVIN-ARNOUX D33N current clamp meter is 30 Hz to 5 kHz. The typical measurement inaccuracy is ≤ 1%.
The CHAUVIN-ARNOUX D series professional current clamps enclose 64 x 150 mm.
Measuring line touch-proof, plug 4mm stackable, blue, 1m
Delivery time upon request
€8.25
About the Manufacturer
Chauvin Arnoux
Chauvin Arnoux stands for highest quality and innovative, highly
reliable test equipment in the fields of electrical safety testing,
measurement of electrical quantities, power measurement, energy and
fault analysis.