Go to homepage

#statusMessage#

Do you want to start the comparison now?

Note
Select at least one product via the “Compare” function to activate the product comparison.

Camille Bauer U584A | SC50-L, split-core current transformer, 300/5 A, 0,5 VA, class 1

Manufacturer number: U584A

Camille Bauer U584A | SC50-L, split-core current transformer

Technical Data

Description

U584A | SC50-L, split-core current transformer, 300/5 A, 0,5 VA, class 1

The Camille Bauer SC50-L, item U584A, is a split-core current transformer for measuring alternating current in electrical distribution systems. The opening design supports installation around existing conductors and is particularly useful in retrofit projects in switchgear and distribution cabinets.

This version has a rated primary current of 300 A and provides a rated secondary current of 5 A. The resulting ratio is 300/5. The connected measuring instrument must have an appropriate secondary input, and the installation must follow the selected metering circuit design.

The rated burden is 0,5 VA. The specified accuracy class is 1. These parameters determine whether the combination of transformer, secondary wiring and instrument is suitable for the required measurement.

The transformer is intended for use with compatible energy meters, power monitors and network measurement equipment. It can support energy-flow documentation, current-load monitoring and the extension of existing measurement points.

The conductor and cable arrangement must fit the mechanical aperture. The SC50-L design has documented inner dimensions of 42 x 85 mm and an aperture of 2 x 42 mm. Selecting the correct version therefore requires consideration of both electrical range and the available installation space.

Installation planning must follow the relevant rules for insulation, secondary wiring and safe handling of current transformer circuits. Assembly and commissioning should be carried out by qualified electrical personnel with verification of the complete metering chain.

Item U584A identifies the specific combination of 300/5, 0,5 VA; class 1 within the SC50-L series. It can therefore be distinguished from versions with different primary currents, secondary currents or physical dimensions.

Product features:

  • Item number: U584A
  • Product series: SC Kabelumbaustromwandler
  • Model / version: SC50-L
  • Device type: split-core current transformer
  • Current transformer ratio: 300/5 A
  • Rated primary current: 300 A
  • Rated secondary current: 5 A
  • Rated burden: 0,5 VA
  • Accuracy class: 1
  • Internal dimensions: 42 x 85 mm
  • Conductor aperture: 2 x 42 mm
  • Housing dimensions (W/H/D): 66 x 139 x 66 mm
  • Principal function: AC current transformation to a secondary measurement current
  • Network frequency: 50-60 Hz
  • Rated voltage: Um 0.72 kV
  • Safety / protection: 3 kV / 50 Hz / 1 min (insulation test)
  • Application: energy meters, power monitoring devices, electrical panels, retrofit
  • Functions: opening core for installation around existing conductors
  • Functions: measuring transformer for compatible secondary inputs
  • Functions: selection by primary/secondary current and burden
  • Functions: installation by qualified electrician

Scope of Delivery:

  • 1 x split-core current transformer SC50-L

Alternate products

Alternate products

U584B
Camille Bauer
U584B
SC50-L, split-core current transformer, 400/5 A, 0,5 VA, class 1
Ready to ship in 5 to 10 business days
On Request
U584C
Camille Bauer
U584C
SC50-L, split-core current transformer, 500/5 A, 0,5 VA, class 1
Ready to ship in 5 to 10 business days
On Request
U584D
Camille Bauer
U584D
SC50-L, split-core current transformer, 600/5 A, 0,5 VA, class 0,5
Ready to ship in 5 to 10 business days
On Request
U584E
Camille Bauer
U584E
SC50-L, split-core current transformer, 750/5 A, 0,5 VA, class 0,5
Ready to ship in 5 to 10 business days
On Request
U584F
Camille Bauer
U584F
SC50-L, split-core current transformer, 800/5 A, 0,5 VA, class 0,5
Ready to ship in 5 to 10 business days
On Request
U584G
Camille Bauer
U584G
SC50-L, split-core current transformer, 1000/5 A, 0,5 VA, class 0,5
Ready to ship in 5 to 10 business days
On Request

About the Manufacturer

Camille Bauer

Camille Bauer Metrawatt AG is a Swiss manufacturer of measurement and monitoring solutions for electrical power systems and is part of the Metrawatt International Group. The company develops and manufactures precision measurement technology for measuring electrical parameters, analysing power quality and monitoring electrical power supply systems.

Last Seen Products