Early prevention, comprehensive certification, targeted troubleshooting. In every area of your data center, measuring instruments from FLUKE and FLUKE Networks help you avoid labor‑intensive and inefficient daily tasks. From installation to monitoring and maintenance of networks and machines: these solutions help reliably safeguard your data center throughout its entire lifecycle and maintain continuous operation.
Test cable connections or protect the power supply against voltage sags with solutions that work for you. The goal is to secure performance, minimize risks, and optimize mission‑critical processes in the most demanding data center environments. Fiber‑optic testing is essential to ensure availability and meet the bandwidth, speed, and latency requirements of today’s data centers. Data centers are evolving very rapidly with the onset of the AI revolution. Stay ahead of these and other increasing requirements with clean and reliable power.
Faster installation, definitive certification, clear documentation
Every centimeter of cable is critical to network reliability, yet problems are difficult to locate within the kilometers of cabling in a data center. Even complex tests are accelerated—from installation to certification through to documentation—helping you identify and resolve issues at the physical layer before they affect performance.
The DSX2‑8000 CableAnalyzer Series copper and fiber cable certifiers are the first field test instruments that indicate the distance to all faults in cable shielding and therefore the true condition of shield continuity. This is particularly important in data centers and Cat 8 installations, where shield continuity ensures the performance of shielded cables in the presence of alien crosstalk.
CertiFiber Pro and CertiFiber Max are Optical Loss Test Sets (OLTS) for certifying fiber optics in high‑density data centers. The Optical Loss Test Sets are designed to quickly and precisely test and certify complex fiber‑optic systems, as performance margins in high‑density data centers continue to become tighter. Measure attenuation, length, and polarity of up to 24 fibers in one second.
MultiFiber Pro testers are MPO (Multifiber Push‑On) testers specialized for installation, maintenance, and troubleshooting in high‑speed data networks. They remove the difficulty of testing MPO trunks for attenuation and polarity. With a built‑in MPO connector, this is the first tester capable of automating the MPO trunk testing procedure without using a fan‑out cable.
FiberInspector Ultra is the industry’s complete solution for fiber inspection. It is the only inspection camera that supports single fiber or MPO. Integrated illumination makes it easy to locate the correct port on densely populated patch panels in poorly lit data centers or dark distribution cabinets. The FI2‑7300 FiberInspector Ultra Kit includes the FI‑3000 camera and a Versiv 2 mainframe.
Safe and reliable power supply from commissioning to operation
Power quality problems such as voltage sags, harmonics, and load imbalance are silent killers. However, not all power problems are obvious. Harmonics can disrupt equipment unnoticed, reduce efficiency, and even lead to costly downtime. With the right measuring instruments and settings, data center operators can detect and correct harmonics before they cause damage.
With the 1775 or 1777 Power Quality Analyzer, you can make harmonic monitoring in the data center a fixed part of your maintenance strategy rather than responding only reactively. The models capture fast voltage transients and also provide advanced measurement functions such as harmonic power calculation, helping determine the direction of harmonics, for example whether the source or the load is responsible.
Monitoring harmonics in data centers is typically carried out using the 1738 Three‑Phase Power Logger to ensure high‑quality measurements. The 1738 Power Logger is the ideal tool for recording and analyzing power parameters, can display voltages and waveforms, and measure and monitor harmonic distortion caused by electrical loads.
The 393 FC True‑RMS Solar Clamp Meter with CAT III 1,500 V safety rating and iFlex current probe is ideal for use in data centers with battery strings for uninterruptible power supply systems as well as in other PV installation and maintenance areas that operate with high DC voltages. The clamp meter measures up to 1,500 V DC and 1,000 V AC via test leads, and up to 999.9 A DC or AC via the clamp.
The 289 multimeter supports the development of high‑voltage sources up to 1,000 V or 1,000 A in both AC and DC ranges. In addition, parameters such as frequency, duty cycle, pulse width, and min/max/avg values can be measured. The integrated data logger and TrendCapture also make it possible to detect difficult‑to‑identify and intermittent problems.
You are not quite sure yet or have further questions about the products? Do not hesitate to contact us. Whether directly on the phone or via online demo conveniently in front of your screen - our experts are there for you.