To be able to use the full range of Shopware 6, we recommend activating Javascript in your browser.
#toastTitle#
#toastText#
Quickly and Easily Request a Quote!
Free Shipping for Orders higher than 50€!
Independent Consulting!
Quickly and Easily Request a Quote!
Free Shipping for Orders higher than 50€!
Independent Consulting!
Company
Any questions?
+43 720 / 51 89 49
Austria | English
Germany | German
Germany | English
Austria | German
Austria | English
Switzerland | German
Switzerland | English
Vergleich
Product
Comparison
0
Select at least one product via the “Compare” function to activate the product comparison.
#statusMessage#
Do you want to start the compare now?
No
Yes
Konto
Customer
Account
Close menu
My Account
Log in
or
sign up
Overview
Your Profile
Addresses
Payment Methods
Orders
Quotes
Requests
Wishlist
Services
Warenkorb
Shopping Cart
& Ouotes
Products
Manufacturers
Seminars
Services
Contact
%SALE%
Oscilloscopes
Power Supplies
Laboratory Meters
Modular Measurement
Multimeter
Thermography
Testers
Tools
Seminars
SALE & Promotions
Product Comparison
EA Elektro-Automatik
33100235
Battery simulation software Li-ion battery, dongle + license
€2,300.00
Delivery time upon request
Add to shopping cart
Teledyne FLIR
Cheer promotion AC02018
Teledyne FLIR C5 thermal imaging camera at a special price
On Request
Add to quote list
Measuring equipment leasing
WEEE take-back
Repair & Calibration
Test equipment
Educational terms
Online-Support
Test equipment
Repair & Calibration
Contact
Close menu
Austria | English
Germany | German
Germany | English
Austria | German
Austria | English
Switzerland | German
Switzerland | English
Show all categories
Multimeter - Comparison
Back
Show Multimeter - Comparison
Home
Products
Product Comparison
Multimeter - Comparison
Multimeter - Comparison
Filter
Filter
Manufacturer
B&K Precision
BEHA
Benning
Chauvin Arnoux
Chroma
FLUKE
Gossen Metrawatt
GW Instek
SEFRAM
Teledyne FLIR
2-/4-wire
2
2-/4
4
Accuracy current measurement AC/DC
AC ±0,2 % - ±11 %
AC ±1 %
AC ±1,8 % / DC ±1,8 % / AC/DC ±2,2 %
AC ±1,8 % / DC ±2,0 % / AC/DC ±2,7 %
AC ±2 %
AC ±3 %
AC ±5 %
DC ±1 %
DC ±2 %
±0,5 % / ±0,5 %
±0,7 % / ±0,7 %
±0,9 % / ±0,9 %
±1 % / ±1 %
±1,5 % / ±0,5 %
±1,5 % / ±1,0 %
±1,5 % / ±1,5 %
±1,8 %
±2 % / ±2 %
±2,0 % / ±1 %
±2,5 % / ±2,5 %
±3,0 % (AC)
Accuracy voltage measurement AC
0,06 %
0,09 %
0,2 %
0,3 %
0,5 %
Accuracy voltage measurement AC/DC
+5 Digits
AC ±0,8 % / DC ±0,8 % / AC/DC ±1,8 %
±0,5 % / ±0,5 %
±0,7 % / ±0,7 %
±0,9 % / ±0,9 %
±1 %
±1 % / ±1 %
±1,2 %
±1,2 % / ±0,5 %
±1,5 % / ±1 %
±2 % / ±2 %
±2,5 % / ±1 %
±3 % / ±1 %
±3 % / ±1,5 %
±3,0 % (AC) / ±1,5 % (DC)
Accuracy voltage measurement DC
0,0035 %
0,0050 %
0,0075 %
0,01 %
0,010 %
0,012 %
0,02 %
0,03 %
Backlight
No
Yes
Basic precision
0,015 %
0,02 %
0,03 %
0,05 %
0,2 %
0,5 %
0,6 %
0,7 %
0,15 %
1 %
1,5 %
2 %
3 %
AC 0,05 %
AC 0,3 % / DC 0,03 %
AC 0,5 % / DC 0,1 %
AC 0,5 % / DC 0,5 %
AC 0,5 % / DC 0,15 %
AC 0,7 % / DC 0,05 %
AC 0,8 % / DC 0,05 %
AC 0,8 % / DC 0,5 %
AC 1 % / DC 0,09 %
AC 1 % / DC 0,4 %
AC 1 % / DC 0,5 %
AC 1 % / DC 0,15 %
AC 1,2 % / DC 0,09 %
AC 1,2 % / DC 0,1 %
AC 1,2 % / DC 0,2 %
AC 1,2 % / DC 0,5 %
AC 1,2 % / DC 0,7 %
AC 1,2 % / DC 0,25 %
AC 1,5 % / DC 0,5 %
AC 1,5 % / DC 0,7 %
AC 1,5 % / DC 1 %
AC 2 % / DC 0,2 %
AC 2 % / DC 0,3 %
AC 2 % / DC 1 %
AC 2,5 % / DC 1,5 %
AC 2,5 % / DC 2 %
ACI Klasse 3 / DCI Klasse 2
DC 0,09 %
DC 0,3 %
Klasse 2
Klasse 2,5
Current measuring range AC
2 mA - 20 A
5 mA - 20 A
10 mA - 10 A
30 mA - 300 A
100 µA - 10 A
500 µA - 10 A
500 µA - 20 A
Current measuring range AC/DC
0 A - 300 A / 0 A - 300 A
0 A - 600 A / 0 A - 600 A
0 A - 1000 A / 0 A - 1000 A
0,1 mA - 20 A / 0,1 mA - 10 A
0,1 μA - 600 A / 0,1 μA - 600 A
0,3 mA - 300 mA / 0,3 mA - 300 mA
0.002A - 10A / 0.002A - 10A
0.1A - 300A / No
0.1µA - 10A / 0.1µA - 10A
0.1µA - 20A / 0.1µA - 20A
0.1µA - 400mA / 0.1µA - 400mA
0.50mA - 5000mA / 50µA - 5000mA
1 A - 600 A / 1 A - 600 A
1 mA - 40 A / 1 mA - 40 A
1.5mA - 15A / 50µA - 15A
1A-10A / 1A-10A
1mA-10A / 1mA-10A
3A - 300A / 50µA - 10A
6A - 10A / 6A - 10A
10 mA - 400 A / 10 mA - 400 A
10 mA - 600 A / 100 nA - 200 μA
10 mA - 1400 A / 10 mA - 2000 A
10 mA - 1500 A / 10 mA - 1500 A
10A / 10A
10mA-10A / 10mA-10A
10µA - 10A / 10µA - 10A
20mA - 10A / 0.1µA - 10A
20mA-10A / 1mA-10A
40mA-10A / 40mA-10A
50 mA - 1 A / 50 mA - 1 A
50 mA - 400 A / 100 mA - 400 A
50 mA - 1000 A / 50 mA - 1400 A
50 mA - 1000 A / 100 mA - 1000 A
50mA - 5A / 50µA - 5A
60mA-10A / 60mA-10A
60mA-400mA / 60mA-400mA
66mA-10A / 66mA-10A
66mA - 660mA / 66mA - 660mA
99,99 A - 599,9 A / 99,99 A - 599,9 A
100 mA - 200 A / 100 mA - 200 A
100 mA - 400 A / 100 mA - 400 A
100 mA - 600 A / 100 mA - 600 A
100 mA - 1000 A / 100 mA - 1000 A
100mA - 200A (AC)
100µA - 3A / 100µA - 3A
100µA - 10A
100µA - 10A / 100µA - 10A
100µA - 100mA / 100µA - 100mA
150 mA - 600 A / 0 A - 900 A
150 mA - 600 A / 10 mA - 900 A
150 mA - 1000 A / 150 mA - 1500 A
150 mA - 1500 A / 0 A - 1500 A
150 mA - 2000 A / 0 A - 3000 A
200 A / 200 A
200µA - 10A / 200µA - 10A
200µA - 200mA / 200µA - 200mA
220µA - 20A / 220µA - 20A
250 mA - 2000 A / 0 mA - 3000 A
300µA - 1A / 300µA - 1A
300µA - 10A / 300µA - 10A
400 A / 400 A
400µA - 10A / 400µA - 10A
400µA - 2000µA / 400µA - 2000µA
500 mA - 400 A / 500 mA - 400 A
500 mA - 400 A / 500 mA - 600 A
500µA - 10A
500µA - 10A / 50µA - 10A
500µA - 10A / 500µA - 10A
600A / 600A
600µA - 10A / 600µA - 10A
600µA - 20A / 600µA - 20A
900 mA - 600 A / 900 mA - 600 A
999.9µA - 9.999A / 999.9µA - 9.999A
1000µA - 20A / 1000µA - 20A
2000 A / 2000 A
6000µA - 6A / 6000µA - 6A
AC 0 A - 600 A
AC 0,01 mA - 60 A
AC 0,1 A - 4000 A
AC 10 mA - 100 A
AC 10 mA - 400 A
AC 10 μA - 60 A
AC 20 mA - 399,9 A
AC 50 mA - 200 A
AC 50 mA - 1000 A
AC 100 mA - 400 A
AC 100 μA - 10 A
AC 150 mA - 600 A
AC 200 mA - 40 A
DC 0 mA - 100 mA
DC 50 mA - 100 mA
DC 100 mA - 200 A
DC 100 mA - 2000 A
No / 600µA - 10A
No no
Current measuring range DC
2 mA - 20 A
5 mA - 20 A
10 mA - 10 A
30 mA - 300 A
100 µA - 10 A
500 µA - 10 A
500 µA - 20 A
Data memory / logger
Ja
No / No
Yes / Yes
Diode test / continuity test
Ja / Ja
No / No
No / Yes
Yes / Yes
Direction of rotation
No
Yes
Display Hold / Auto-Hold
No / No
No / Yes
Yes / No
Yes / Yes
Display resolution
1999
2000
3100
3999
4000
4200
5000
6000
6600
9999
10000
11999
12000
20000
22000
30000
31000
40000
50000
59999
60000
100000
310000
Electrical safety
CAT I 50 V
CAT II 300 V
CAT II 600 V, CAT III 300 V
CAT II 600 V, CATIII 300 V
CAT II 1000 V, CAT III 600 V
CAT II 1000 V, CAT III 600 V, CAT IV 300 V
CAT II 1000 V, CAT IV 600 V
CAT III 300 V
CAT III 600 V
CAT III 600 V, CAT IV 300 V
CAT III 600 V, CAT IV 600 V
CAT III 1000 V, CAT IV 600 V
CAT IV 600 V
Enclosure (mm)
4.5
15.5
16
17.8
18
23
25
26
27
28
30
30.5
32
33
34
35
37
40
42
45
48
51
53
55
58
60
61
64
70
100
Frequency measuring range
0 Hz - 99,99 kHz
0 Hz - 2000 Hz
0,01 Hz - 10 kHz
0,01 Hz - 50 kHz
0,01 Hz - 100 kHz
0,1 Hz - 100 kHz
0,2 Hz - 9999 Hz
0,5 Hz - 199,99 kHz
1 Hz - 1 kHz
1 Hz - 400 Hz
1 mHz - 5 MHz
2 Hz - 1 MHz
2 Hz - 1 kHz
2,2 Hz - 1 MHz
3 Hz - 1 MHz
3,3 Hz - 1 MHz
4 kHz - 1 MHz
4 kHz - 400 kHz
5 Hz - 1 MHz
5 Hz - 1 kHz
5 Hz - 20 kHz
5 Hz - 500 Hz
5 Hz - 999,9 Hz
10 Hz - 1 MHz
10 Hz - 1 MHz (V) / 20 Hz - 10 kHz (A)
10 Hz - 1 kHz
10 Hz - 5 MHz
10 Hz - 10 MHz
10 Hz - 10 kHz
10 Hz - 30 kHz
10 Hz - 100 kHz
10 Hz - 220 MHz
10 Hz - 500 kHz
10 Hz - 800 kHz
10 Hz - 1000 kHz
10 kHz
10 mHz - 50 kHz
10 mHz - 100 kHz
40 Hz - 1 kHz
40 Hz - 100 kHz
40 Hz - 400 kHz
45 Hz - 66 Hz
45Hz - 66Hz
50 Hz - 400 Hz
60 Hz - 600 kHz
60Hz - 600kHz
66 Hz - 10 MHz
99,99 Hz - 9,999 MHz
99,99 Hz - 9,999 kHz
99,99 Hz - 50 kHz
99,99 Hz - 99,99 kHz
99,99 Hz - 999,9 Hz
99,99 Hz - 999,99 kHz
99,99Hz - 50kHz
99,99Hz - 99,99kHz
100 Hz - 1 MHz
100 Hz - 1 kHz
100 Hz - 10 MHz
100 Hz - 100 kHz
100 Hz - 1000 Hz
199,99 Hz - 200 kHz
300 Hz - 1 MHz
300 Hz - 30 kHz
300 Hz - 300 kHz
300 Hz - 1000 kHz
400 Hz - 100 kHz
500 Hz - 100 kHz
600 Hz - 1 MHz
600 Hz - 50 kHz
600 Hz - 300 kHz
No
bis 3k Hz
Hold
No
Yes
Interfaces
Bluetooth
Bluetooth, WiFi Optional: USB
Bluetooth, mini USB
Bluetooth/USB optical
IR-USB, Bluetooth
IR USB
None
None
RS-232
RS-232, optional GPIB
USB
USB, GPIB, BNC
USB, GPIB, RS-232
USB, LAN, RS-232
USB, LAN, RS-232, Digital I/O, optional: GPIB
USB, LAN, RS-232, GPIB
USB, RS-232
USB, RS-232, Digital I/O
USB, RS-232, LAN, Optional: GPIB
USB, RS-232, optional: GPIB
Wireless
Wireless, mini USB
opt. Bidirectional IR/USB adapter
Measurement method
Average
RMS
TRMS
Measurements per second
25
40
60
320
1000
10000
Min. / Max. Measurement
Ja / Ja
Nein
No / No
No / Yes
Yes
Yes / Yes
Min. / Max. Recording
No / No
No / Yes
Yes / No
Yes / Yes
Number of positions
3
3.5
3.75
3.83
3.85
4
4.5
4.75
4.83
4.85
5
5.5
5.75
6.5
8
Power measurement (active / apparent / reactive)
0 W - 900 kW / Ja / Ja
0 W - 1500 kW / 5 VA - 1000 kVA / 5 VAr - 1500 kVAr
1W - 600kW / No / No
Ja / Ja / Ja
No / 5VA - 900kVA / 5var - 900kvar
No / No / No
No / Yes (DC) / No
Resistance measuring range
0 Ω - 60 kΩ
0 Ω - 100 kΩ
0,01 Ω - 40 MΩ
0,1 Ω - 20 MΩ
0,1 Ω - 40 MΩ
0,1 Ω - 42 MΩ
0,1 Ω - 50 MΩ
0,1 Ω - 600 kΩ
0,1 Ω - 40 MΩ
1 mΩ - 50 MΩ
1 Ω - 1 MΩ
1 Ω - 10 kΩ
1 Ω - 40 MΩ
1 Ω - 50 kΩ
1 Ω - 60 MΩ
1 Ω - 100 kΩ
1Ohm - 100kOhm
3 mΩ - 30 MΩ
3 mΩ - 3000 mΩ
5 mΩ - 5 MΩ
6 kΩ
10 kΩ - 1 MΩ
10 mΩ - 1500 Ω
10 Ω - 2 MΩ
10 Ω - 100 MΩ
20 kΩ - 2 MΩ
20 mΩ - 2 MΩ
30 mΩ - 30 Ω
30 Ω - 30 MΩ
40 MΩ
60 MΩ
60 kΩ
100 mΩ - 1 kΩ
100 mΩ - 4 kΩ
100 mΩ - 6 kΩ
100 mΩ - 20 MΩ
100 mΩ - 40 MΩ
100 mΩ - 40 kΩ
100 mΩ - 60 kΩ
100 mΩ - 100 kΩ
100 mΩ - 600 kΩ
100 Ω - 40 MΩ
100 Ω - 100 MΩ
100 Ω - 1000 MΩ
200 mΩ - 399,9 Ω
200 mΩ - 4000 Ω
200 Ω - 20 MΩ
220 Ω - 220 MΩ
300 mΩ - 9999 Ω
300 Ω - 30 MΩ
400 Ω - 4 MΩ
400 Ω - 40 MΩ
500 Ω - 20 MΩ
500 Ω - 50 MΩ
500 Ω - 500 MΩ
600 Ω - 6 MΩ
600 Ω - 40 MΩ
600 Ω - 50 MΩ
600 Ω - 60 MΩ
600Ω - 40MΩ
600Ω - 60MΩ
600Ω - 60kΩ
660 Ω - 66 MΩ
999,9 Ω - 99,99 MΩ
999,9 Ω - 99,99 kΩ
1000 Ω - 40 MΩ
No
Resolution current measurement AC/DC
+3 Digits
+5 Digits
+10 Digits
1 A / 1 A
1 mA - 1000 A / 1 mA - 1000 A
1 mA / 1 mA
10 mA - 1 A / 10 mA - 1 A
10 mA / 10 mA
100 mA / 100 mA
100 mA / 100 nA
100 μA
100mA (AC)
AC +5 Digits / DC +5 Digits / AC/DC +7 Digits
AC 1 mA
AC 1 μA
AC 1 μA - 10 mA
AC 100 mA
DC 10 mA
DC 100 mA
Temperature measurement
No
Yes
Temperature measurement ( PT100 / Type K / Type J)
-40°C - +400°C
-40°C - +537°C / Type-K
-40°C - +1000°C
-50°C - +400°C
-50°C - +800°C
-50°C - +850°C
-50°C - +1300°C
-200°C - +1090°C
-200°C - +1350°C
0 °C - +60 °C
No
PT100 / Type K / Type J
Pt100
Pt100 / Pt1000
Pt 100 / Pt 1000 / Type K
Pt100 / Type K
Type K
Yes
Temperature measuring range
-10 °C - +150 °C
-10 °C - +400 °C
-40 °C - +400 °C
-40 °C - +1200 °C
-50 °C - +1000 °C
-60 °C - +1200 °C
10 °C - +400 °C
No
True effective measurement TRMS
No
Yes
Voltage measuring range AC
100 mV - 750 V
200 mV - 600 V
200 mV - 750 V
500 mV - 750 V
500 mV - 1000 V
Voltage measuring range AC/DC
0 V - 600 V / 0 V - 600 V
0 V - 1000 V / 0 V - 1000 V
0,1 mV - 600 V / 0,1 mV - 600 V
0,1 mV - 1000 V / 0,1 mV - 1000 V
0,4 V - 600 V / 0,4 V - 600 V
0,6 V - 750 V / 0,6 V - 1000 V
1 V - 1000 V / 1 V - 1000 V
1 mV - 600 V / 1 mV - 600 V
1 mV - 600 V / 1 mV - 1000 V
1 mV - 600 V / 1 mv - 600 V
1 mV / 1mV
1,3 V - 750 V / 0,7 V - 1000 V
1,5 V - 500 V / 0,15 V - 500 V
1V - 1000V (AC) / 1V - 1000V (DC)
2 V - 600 V / 200 mV - 600 V
3 V - 300 V / 100 mV - 300 V
5 V - 1,5 kV / 150 mV - 1,5 kV
6 V - 600 V / 6 V - 450 V
6 V - 1000 V / 600 mV - 1000 V
6V - 600V / 6V - 600V
6V - 600V / 600mV - 600V
6V - 1000V / 600mV - 1000V
9,999 mV - 999,9 V / 9,999 mV - 999,9 V
10 V - 1000 V / 100 mV - 1000 V
10 mV - 600 V / 10 mV - 600 V
10 mV - 1000 V / 10 mV - 1000 V
10 µV - 1000 V / 10 µV - 1000 V
40 mV - 1000 V / 40 mV - 1000 V
50 mV - 1000 V
50 mV - 1000 V / 50 mV - 1000 V
60 mV - 300 V / 60 mV - 300 V
60 mV - 600 V / 60 mV - 600 V
60 mV - 1000 V / 60 mV - 1000 V
60 mV - 1000V / 60mV - 1000V
99,99 V - 999,9 V / 99,99 V - 999,9 V
100 mV - 600 V / 100 mV - 600 V
100 mV - 750 V / 100 mV - 1000 V
100 mV - 1000 V
100 mV - 1000 V / 0,1 mV - 1000 V
100 mV - 1000 V / 100 mV - 1000 V
100 mV - 1000V / 100 mV - 1500 V
100 µV - 600 V / 100 µV - 600 V
100 µV - 750 V / 100 µV - 1000 V
100 µV - 1000 V / 100 µV - 1000 V
150 mV - 1000 V / 100 mV - 1000 V
150 mV - 1400 V / 0 mV - 1000 V
200 mV - 600 V / 200 mV - 600 V
220 mV - 1000 V / 220 mV - 1000 V
300 mV - 600 V / 30 mV - 600 V
300 mV - 600 V / 300 mV - 600 V
300 mV - 1000 V / 300 mV - 1000 V
400 mV - 600 V / 400 mV - 600 V
400 mV - 750 V / 400 mV - 1000 V
400 mV - 1000 V / 400 mV - 1000 V
500 mV - 600 V / 200 mV - 600 V
500 mV - 600 V / 500 mV - 600 V
500 mV - 750 V / 200 mV - 1000 V
500 mV - 1000 V / 200 mV - 1400 V
600 V / 600 V
600 V / 600 mV - 600 V
600 mV - 600 V / 6 V - 1000 V
600 mV - 600 V / 600 mV - 600 V
600 mV - 1000 V / 60 mV - 1000 V
600 mV - 1000 V / 600 mV - 1000 V
660 mV - 1000 V / 660 mV - 1000 V
1000 V / 1000 V
1000 mV - 750 V / 1000 mV - 1000 V
AC 0 V - 600
max. Measuring range DC (V)
1000
2400
min. Measuring range DC (mV)
100
200
500
20000
Immediately available
Filter
210 products
Recommendations
Available immediately
New in the Shop
Event date
Price ascending
Price descending
Name A-Z
Name Z-A
FLUKE
87V-MAX
True RMS digital multimeter
Data memory / logger: No / No
True effective measurement TRMS: Yes
Number of positions: 4.5
Backlight: Yes
Electrical safety: CAT III 1000 V, CAT IV 600 V
Current measuring range AC/DC: 0.1µA - 10A / 0.1µA - 10A
Frequency measuring range: 0,5 Hz - 199,99 kHz
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Basic precision: 1 %
Diode test / continuity test: Yes / Yes
Display resolution: 20000
Resistance measuring range: 0,1 Ω - 50 MΩ
Voltage measuring range AC/DC: 0,1 mV - 1000 V / 0,1 mV - 1000 V
Temperature measurement ( PT100 / Type K / Type J): -200°C - +1090°C
+ More Features
- Less Features
On Request
Reordered - in stock. Delivery time on request
Add to quote list
FLUKE
FLUKE-378 FC / E
True effective clamp meter 378, Fluke Connect, 2,500 A, 60 kOhm 1000V, CAT III 1000V, CAT IV 600
Hold: Yes
Measurement method: TRMS
Number of positions: 4
Min. / Max. Measurement: Yes / Yes
Direction of rotation: No
Current measuring range AC/DC: 100 mA - 1000 A / 100 mA - 1000 A
Enclosure (mm): 34
Resistance measuring range: 100 mΩ - 60 kΩ
Voltage measuring range AC/DC: 100 mV - 1000 V / 100 mV - 1000 V
Accuracy current measurement AC/DC: ±2 % / ±2 %
Accuracy voltage measurement AC/DC: ±1 % / ±1 %
Resolution current measurement AC/DC: 100 mA / 100 mA
Temperature measuring range: No
Diode test / continuity test: No / Yes
Frequency measuring range: 5 Hz - 500 Hz
Power measurement (active / apparent / reactive): No / No / No
+ More Features
- Less Features
On Request
Delivery time upon request
Add to quote list
Benning
044087
Multimeter MM6-2
Data memory / logger: No / No
True effective measurement TRMS: Yes
Backlight: Yes
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Number of positions: 4
Resistance measuring range: 0,1 Ω - 40 MΩ
Current measuring range AC/DC: 20mA-10A / 1mA-10A
Temperature measurement ( PT100 / Type K / Type J): Type K
Display resolution: 6000
Frequency measuring range: 0,01 Hz - 100 kHz
Voltage measuring range AC/DC: 100 µV - 1000 V / 100 µV - 1000 V
Electrical safety: CAT IV 600 V
Basic precision: 0,5 %
+ More Features
- Less Features
€216.40
Delivery time upon request
Add to shopping cart
FLUKE
771
Current clamp, measuring mA process
Hold: Yes
Measurement method: TRMS
Direction of rotation: No
Temperature measuring range: No
Power measurement (active / apparent / reactive): No / No / No
Accuracy current measurement AC/DC: AC ±0,2 % - ±11 %
Diode test / continuity test: No / No
Number of positions: 3.5
Resistance measuring range: No
Enclosure (mm): 4.5
Resolution current measurement AC/DC: AC 1 mA
Current measuring range AC/DC: DC 0 mA - 100 mA
Min. / Max. Measurement: No / No
Frequency measuring range: No
+ More Features
- Less Features
On Request
Delivery time upon request
Add to quote list
FLUKE
369-FC
Leakage current clamp 61mm, TRMS, up to 60A, 3300 digits, Fluke Connect
Hold: Yes
Measurement method: TRMS
Number of positions: 4
Min. / Max. Measurement: Yes / Yes
Direction of rotation: No
Temperature measuring range: No
Power measurement (active / apparent / reactive): No / No / No
Diode test / continuity test: No / No
Resistance measuring range: No
Accuracy current measurement AC/DC: AC ±1 %
Current measuring range AC/DC: AC 10 μA - 60 A
Frequency measuring range: 40 Hz - 1 kHz
Enclosure (mm): 61
Resolution current measurement AC/DC: AC 1 μA
+ More Features
- Less Features
On Request
1 in stock. Ready to ship in 1 business day
Add to quote list
Benning
044679
CM P2 current probe, digital, RMS AC / DC 0.001 - 400A, 4 digits
Hold: Yes
Measurement method: TRMS
Number of positions: 4
Direction of rotation: No
Accuracy current measurement AC/DC: ±2 % / ±2 %
Temperature measuring range: No
Power measurement (active / apparent / reactive): No / No / No
Diode test / continuity test: No / No
Resistance measuring range: No
Min. / Max. Measurement: No / No
Frequency measuring range: No
Enclosure (mm): 23
Current measuring range AC/DC: 10 mA - 400 A / 10 mA - 400 A
+ More Features
- Less Features
€138.00
Delivery time upon request
Add to shopping cart
GW Instek
GDM-533
Handheld Digital Multimeter, 6000 Counts, CAT IV 600V, 20A AC/DC, TRMS, USB, GDM-500 Series,
Data memory / logger: No / No
True effective measurement TRMS: Yes
Number of positions: 4.5
Backlight: Yes
Electrical safety: CAT III 1000 V, CAT IV 600 V
Min. / Max. Recording: Yes / Yes
Diode test / continuity test: Yes / Yes
Display resolution: 6000
Current measuring range AC/DC: 600µA - 20A / 600µA - 20A
Display Hold / Auto-Hold: Yes / No
Basic precision: AC 1 % / DC 0,5 %
Resistance measuring range: 600 Ω - 60 MΩ
Voltage measuring range AC/DC: 60 mV - 1000 V / 60 mV - 1000 V
Interfaces: USB
Temperature measurement ( PT100 / Type K / Type J): -40°C - +1000°C
Frequency measuring range: 10 Hz - 10 MHz
+ More Features
- Less Features
€95.00
Delivery time upon request
Add to shopping cart
FLUKE
FLK-3000FC
Multimeter, hand 4 digits, LCD display Fluke Connect
True effective measurement TRMS: Yes
Backlight: Yes
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Number of positions: 4
Display resolution: 6000
Data memory / logger: Yes / Yes
Resistance measuring range: 600 Ω - 50 MΩ
Current measuring range AC/DC: 60mA-400mA / 60mA-400mA
Frequency measuring range: 99,99Hz - 99,99kHz
Temperature measurement ( PT100 / Type K / Type J): No
Electrical safety: CAT III 600 V, CAT IV 300 V
Interfaces: Wireless
Voltage measuring range AC/DC: 600 mV - 1000 V / 600 mV - 1000 V
Basic precision: 1,5 %
+ More Features
- Less Features
On Request
Reordered - in stock. Delivery time on request
Add to quote list
Gossen Metrawatt
M242A
Metrahit PRO multimeter, hand 4 ½ digits, 12,000 digits, DAkks
Data memory / logger: No / No
True effective measurement TRMS: Yes
Number of positions: 4.5
Backlight: Yes
Electrical safety: CAT III 1000 V, CAT IV 600 V
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Voltage measuring range AC/DC: 100 mV - 1000 V / 100 mV - 1000 V
Temperature measurement ( PT100 / Type K / Type J): Type K
Resistance measuring range: 100 Ω - 40 MΩ
Frequency measuring range: 100 Hz - 100 kHz
Current measuring range AC/DC: 1A-10A / 1A-10A
Display resolution: 12000
Basic precision: 0,05 %
Interfaces: None
+ More Features
- Less Features
€525.00
Ready to ship in 5 to 10 business days
Add to shopping cart
Benning
044067
CM11 clamp meter, digital, CAT IV 300V TRMS, AC / DC, 20A / 10A, 0.1 mA resolution
Hold: Yes
Measurement method: TRMS
Number of positions: 4
Min. / Max. Measurement: Yes / Yes
Direction of rotation: No
Accuracy voltage measurement AC/DC: ±1 % / ±1 %
Temperature measuring range: No
Diode test / continuity test: No / Yes
Power measurement (active / apparent / reactive): No / No / No
Frequency measuring range: No
Enclosure (mm): 23
Current measuring range AC/DC: 0,1 mA - 20 A / 0,1 mA - 10 A
Resistance measuring range: 0,1 Ω - 600 kΩ
Voltage measuring range AC/DC: 10 mV - 600 V / 10 mV - 600 V
Accuracy current measurement AC/DC: ±1 % / ±1 %
+ More Features
- Less Features
€388.80
Delivery time upon request
Add to shopping cart
Gossen Metrawatt
METRAHIT PM PRIME BT (formerly ULTRA BT)
Multimeter, TRMS, 4 6/7, ± 0.02% VDC, Bluetooth
True effective measurement TRMS: Yes
Backlight: Yes
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Data memory / logger: Yes / Yes
Electrical safety: CAT III 600 V, CAT IV 300 V
Interfaces: None
Current measuring range AC/DC: 300µA - 10A / 300µA - 10A
Number of positions: 5.75
Temperature measurement ( PT100 / Type K / Type J): Pt100 / Type K
Voltage measuring range AC/DC: 300 mV - 600 V / 300 mV - 600 V
Basic precision: 0,02 %
Frequency measuring range: 300 Hz - 1 MHz
Display resolution: 310000
Resistance measuring range: 300 Ω - 30 MΩ
+ More Features
- Less Features
€1,102.00
Delivery time upon request
Add to shopping cart
Benning
044088
Multimeter MM12
True effective measurement TRMS: Yes
Backlight: Yes
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Resistance measuring range: 0,1 Ω - 40 MΩ
Temperature measurement ( PT100 / Type K / Type J): Type K
Electrical safety: CAT IV 600 V
Basic precision: 0,5 %
Data memory / logger: Yes / Yes
Voltage measuring range AC/DC: 10 µV - 1000 V / 10 µV - 1000 V
Number of positions: 4.75
Frequency measuring range: 0,1 Hz - 100 kHz
Display resolution: 4000
Current measuring range AC/DC: 10µA - 10A / 10µA - 10A
Interfaces: Bluetooth/USB optical
+ More Features
- Less Features
€517.00
Delivery time upon request
Add to shopping cart
Gossen Metrawatt
M243A
Metrahit TECH multimeter, hand 4 ½ digits, 12,000 digits, DAkkS
Data memory / logger: No / No
True effective measurement TRMS: Yes
Number of positions: 4.5
Backlight: Yes
Electrical safety: CAT III 1000 V, CAT IV 600 V
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Voltage measuring range AC/DC: 100 mV - 1000 V / 100 mV - 1000 V
Temperature measurement ( PT100 / Type K / Type J): Type K
Resistance measuring range: 100 Ω - 40 MΩ
Frequency measuring range: 100 Hz - 100 kHz
Basic precision: 0,05 %
Display resolution: 11999
Current measuring range AC/DC: 10mA-10A / 10mA-10A
+ More Features
- Less Features
€591.00
Ready to ship in 5 to 10 business days
Add to shopping cart
Chauvin Arnoux
MX1
MX 1 multimeter, analog with test leads, battery
Data memory / logger: No / No
True effective measurement TRMS: Yes
Diode test / continuity test: Yes / Yes
Frequency measuring range: No
Temperature measurement ( PT100 / Type K / Type J): No
Min. / Max. Recording: No / No
Electrical safety: CAT III 600 V
Current measuring range AC/DC: 500µA - 10A / 50µA - 10A
Backlight: No
Basic precision: AC 2,5 % / DC 2 %
Resistance measuring range: 10 Ω - 2 MΩ
Voltage measuring range AC/DC: 5 V - 1,5 kV / 150 mV - 1,5 kV
Display Hold / Auto-Hold: No / No
+ More Features
- Less Features
€284.00
Ready to ship in 5 to 10 business days
Add to shopping cart
Gossen Metrawatt
M102A
Metramax 2 multimeter, analog
Data memory / logger: No / No
Diode test / continuity test: No / No
Resistance measuring range: No
Frequency measuring range: No
Temperature measurement ( PT100 / Type K / Type J): No
Min. / Max. Recording: No / No
Backlight: No
Display Hold / Auto-Hold: No / No
Voltage measuring range AC/DC: 3 V - 300 V / 100 mV - 300 V
Basic precision: ACI Klasse 3 / DCI Klasse 2
True effective measurement TRMS: No
Electrical safety: CAT III 300 V
Current measuring range AC/DC: 100µA - 3A / 100µA - 3A
+ More Features
- Less Features
€273.00
Ready to ship in 5 to 10 business days
Add to shopping cart
Gossen Metrawatt
M206A
Metrahit WORLD multimeter, hand 3 6/7 digits, DAkkS calibration certificate
Data memory / logger: No / No
True effective measurement TRMS: Yes
Backlight: Yes
Electrical safety: CAT III 1000 V, CAT IV 600 V
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Display resolution: 6000
Basic precision: 0,5 %
Voltage measuring range AC/DC: 600 mV - 1000 V / 600 mV - 1000 V
Temperature measurement ( PT100 / Type K / Type J): -50°C - +800°C
Number of positions: 3.85
Interfaces: opt. Bidirectional IR/USB adapter
Resistance measuring range: 600 Ω - 40 MΩ
Current measuring range AC/DC: 60mA-10A / 60mA-10A
Frequency measuring range: 10 Hz - 1000 kHz
+ More Features
- Less Features
€431.00
1 in stock. Ready to ship in 1 business day
Add to shopping cart
FLUKE
FLUKE 28IIEX
Multimeter, hand intrinsically safe (Ex area)
Data memory / logger: No / No
True effective measurement TRMS: Yes
Number of positions: 4.5
Backlight: Yes
Electrical safety: CAT III 1000 V, CAT IV 600 V
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Display resolution: 20000
Temperature measurement ( PT100 / Type K / Type J): -200°C - +1090°C
Resistance measuring range: 600 Ω - 50 MΩ
Voltage measuring range AC/DC: 600 mV - 1000 V / 600 mV - 1000 V
Basic precision: 0,7 %
Current measuring range AC/DC: 600µA - 10A / 600µA - 10A
Frequency measuring range: 199,99 Hz - 200 kHz
+ More Features
- Less Features
On Request
1 in stock. Ready to ship in 1 business day
Add to quote list
Gossen Metrawatt
M241A
Metrahit BASE multimeter, hand 4 ½ digits, 12,000 digits, DAkkS
Data memory / logger: No / No
True effective measurement TRMS: Yes
Number of positions: 4.5
Backlight: Yes
Electrical safety: CAT III 1000 V, CAT IV 600 V
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Resistance measuring range: 100 Ω - 40 MΩ
Display resolution: 12000
Basic precision: 0,05 %
Interfaces: None
Temperature measurement ( PT100 / Type K / Type J): -50°C - +850°C
Current measuring range AC/DC: 100µA - 10A
Frequency measuring range: 100 Hz - 1 kHz
Voltage measuring range AC/DC: 100 mV - 1000 V
+ More Features
- Less Features
€434.00
Ready to ship in 5 to 10 business days
Add to shopping cart
Gossen Metrawatt
M234D
Metraport 40S multimeter, hand 4 3/4 digits, folding display, DAkkS calibration certificate
Data memory / logger: No / No
True effective measurement TRMS: Yes
Backlight: Yes
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Interfaces: USB
Basic precision: 0,05 %
Current measuring range AC/DC: 300µA - 10A / 300µA - 10A
Temperature measurement ( PT100 / Type K / Type J): Pt100 / Type K
Number of positions: 4.75
Frequency measuring range: 300 Hz - 1000 kHz
Voltage measuring range AC/DC: 300 mV - 600 V / 30 mV - 600 V
Resistance measuring range: 30 Ω - 30 MΩ
Electrical safety: CAT II 300 V
Display resolution: 31000
+ More Features
- Less Features
€898.00
Ready to ship in 5 to 10 business days
Add to shopping cart
FLUKE
177
Multimeter, handheld, 3 3/4 digits, 6000 digits, 1000V, CAT III 1000V
Data memory / logger: No / No
True effective measurement TRMS: Yes
Backlight: Yes
Electrical safety: CAT III 1000 V, CAT IV 600 V
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Display resolution: 6000
Number of positions: 3.5
Resistance measuring range: 600 Ω - 50 MΩ
Temperature measurement ( PT100 / Type K / Type J): No
Voltage measuring range AC/DC: 600 mV - 1000 V / 600 mV - 1000 V
Current measuring range AC/DC: 60mA-10A / 60mA-10A
Frequency measuring range: 99,99 Hz - 99,99 kHz
Basic precision: 3 %
+ More Features
- Less Features
On Request
11 in stock. Ready to ship in 1 business day
Add to quote list
Gossen Metrawatt
METRAHIT PM XTRA (formerly EXTRA)
Multimeter, TRMS, 4 6/7, ± 0.05% VDC, data logger (M250A)
True effective measurement TRMS: Yes
Backlight: Yes
Electrical safety: CAT III 1000 V, CAT IV 600 V
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Temperature measurement ( PT100 / Type K / Type J): Type K
Data memory / logger: Yes / Yes
Voltage measuring range AC/DC: 600 mV - 1000 V / 600 mV - 1000 V
Basic precision: 0,05 %
Interfaces: None
Current measuring range AC/DC: 600µA - 10A / 600µA - 10A
Resistance measuring range: 600 Ω - 6 MΩ
Number of positions: 4.85
Display resolution: 59999
Frequency measuring range: 600 Hz - 1 MHz
+ More Features
- Less Features
€991.00
Ready to ship in 5 to 10 business days
Add to shopping cart
FLUKE
115
Multimeter, handheld, TRMS 4 digits, CAT III / 600 V
Data memory / logger: No / No
True effective measurement TRMS: Yes
Backlight: Yes
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Number of positions: 4
Display resolution: 6000
Temperature measurement ( PT100 / Type K / Type J): No
Electrical safety: CAT III 600 V
Resistance measuring range: 600 Ω - 40 MΩ
Basic precision: 3 %
Frequency measuring range: 99,99 Hz - 50 kHz
Voltage measuring range AC/DC: 600 mV - 600 V / 600 mV - 600 V
Current measuring range AC/DC: 6A - 10A / 6A - 10A
+ More Features
- Less Features
On Request
52 in stock. Ready to ship in 1 business day
Add to quote list
Gossen Metrawatt
M244A
Metrahit CAL process calibrator 18 calibration functions, DAkkS calibration certificate
€1,614.00
Ready to ship in 5 to 10 business days
Add to shopping cart
Gossen Metrawatt
M272S
METRAHITE IN TECH BT
True effective measurement TRMS: Yes
Backlight: Yes
Electrical safety: CAT III 1000 V, CAT IV 600 V
Min. / Max. Recording: Yes / Yes
Display Hold / Auto-Hold: Yes / Yes
Diode test / continuity test: Yes / Yes
Data memory / logger: Yes / Yes
Number of positions: 4.75
Display resolution: 31000
Temperature measurement ( PT100 / Type K / Type J): Pt 100 / Pt 1000 / Type K
Frequency measuring range: 300 Hz - 300 kHz
Resistance measuring range: 3 mΩ - 30 MΩ
Current measuring range AC/DC: 300µA - 1A / 300µA - 1A
Voltage measuring range AC/DC: 300 mV - 1000 V / 300 mV - 1000 V
Basic precision: 0,15 %
Interfaces: Bluetooth, WiFi Optional: USB
+ More Features
- Less Features
€2,181.00
Ready to ship in 5 to 10 business days
Add to shopping cart