GI2K-SI series - AC pulse current sources (pulse current generators)
The GI2K-SI series from Zenone Elettronica are static AC constant current sources for high-precision testing and calibration tasks. The devices supply a very stable alternating current over a wide load spectrum and support both sinusoidal and freely definable (arbitrary) output forms. Depending on the version, up to three current ranges (scales) with manual or automatic switching are available. Thanks to the sequencer timer, synchronization and various interfaces, the systems are equally suitable for laboratory setups and automated test lines.
Call us or send us a request for a quote, we will be happy to advise you and work with you to configure the optimum system for your application:
General features and possible applications
- Switchgear and protection technology: Thermal and magnetic tests on switches, fuses, relays, trip units including precise trip time measurement.
- Heating and contact tests: Thermal tests on contacts, cables, connection points and transitions.
- Inductors & transformers: Tests on transformers, coils, cores and winding goods.
- Measuring equipment: Testing and calibration of measuring devices and instrument transformers.
- Automation: Control via serial communication and integration via programmable digital inputs and outputs; analog input (booster) for use as a power amplifier.
- Scalability: Parallel connection for higher total power and higher currents as well as synchronization for polyphase systems.
Available models in the series
The GI2K-SI series is offered in several power and current classes. The selection is typically made according to the required maximum current, required output power and desired design.
Models according to available power
- 5 kVA
- 7.5 kVA
- 10 kVA
- 15 kVA
- 20 kVA
- 30 kVA
- 50 kVA
- 75 kVA
- 100 kVA
- 150 kVA
- 200 kVA
- 300 kVA
Models according to available maximum current
- 900 A
- 1300 A
- 2500 A
- 3500 A
- 5000 A
- 6000 A
- 8000 A
- 10 kA
- 20 kA
- 30 kA
- 40 kA
- Further current values on request
Call us or send us a request for quotation, we will be happy to advise you and configure the optimum system for your application together with you:
Available designs
- Horizontal Built-in Rack
- Vertical Built-in Rack
- Table RackRack (Table Rack)
- Wheeled Cabinet
- Cabinet version
- Separate electronics and power section for board mounting
Model options and additional options
Depending on the project, the GI2K-SI systems can be equipped with hardware and software options. These include additional communication interfaces, alternative connection arrangements and variants for installation in test benches and systems.
Options / finishings on request
- /M-GI-SW Software GImanager with 1-phase arbitrary function
- /M3-GI-SW Software GImanager with 3-phase arbitrary function
- /Rack Rack for built-in mounting (up to 5 kVA)
- /Rack-V Rack for vertical built-in mounting (up to 5 kVA)
- /3-Rack Cabinet with three phase-synchronized sources
- /LAN LAN interface
- /USB USB-interface
- /Rout Output on the rear panel
- /Fout Output on the front panel
- /Sout Access to special output configuration (to be specified) output configuration (to be specified)
- /ATE Version without display
- /Cons Separate operating unit (3 m cable)
- /F-I/O I/O and serial connections on the front panel
- /R-I/O I/O and serial connections on the rear panel
- /F-ms Main switch on the front panel
- /R-ms Main switch on the rear panel
Product features of the series:
- Output current: 900 A to 40 kA (depending on model)
- Output power: 600 VA to 300 kVA (depending on model)
- Output frequency: 40 to 200 Hz, resolution 0.01 Hz, accuracy 0.15%
- Bandwidth: 500 Hz
- Current ranges (scales): 1 to 3, manually or automatically switchable
- Current resolution: 0.3% F.S.; smallest adjustable current: 1/20 F.S.
- Accuracy: typ. 0.3% F.S. (current), voltage measurement 0.5%
- Control behavior: Line regulation typ. 0.1% F.S.; Load regulation typ. 0.2% F.S.; Linearity 0.1% F.S.
- Distortion factor (THD): typ. 0.2% at 50-60 Hz
- Sequencer timer: 1 ms to infinity, resolution 1 ms, up to 30 steps, modes including Auto-repeat, ramp, pause/resume, continuous or pulsed
- Synchronization & phase shift: Auto / mains / external; phase shift 0-360°, resolution 1°, accuracy ±1°; start angle 0-360°
- Additional measurements: Power factor (PF), impedance, frequency
- Supply: 230 V 1~ ±10% or 400 V 3~ ±10%; 45-65 Hz; cos(phi) typ. 0.85; line protection via automatic
- Interfaces: RS232 and RS485 (isolated); optional USB, LAN, fiber optics; Trig-in/Trig-out
- Digital I/O: 4 digital inputs (24 V NPN, programmable) and 4 digital outputs (24 V PNP, programmable)
- Analog booster input: 0 to 20 pk-pk (use as power amplifier)
- Isolation: Mains/Output/GND 2500 Vrms; Output/GND 1500 Vrms; isolated output
- Environment: Operation 5 to 40 °C; Storage -5 to 60 °C; Protection class IP20; Forced air cooling; Noise level typ. 65 dBA (1 m)
- Standards: CE (EMC and LVD)
- Scaling: Parallel connection up to 1 MVA or 100 kA; synchronizable for polyphase systems
- Output forms: sinusoidal or freely programmable (arbitrary), depending on version/software
Call us or send us a request for quotation, we will be happy to advise you and configure the optimum system for your application together with you: