GI2K series - AC current sources for high-current tests
The AC current sources in the GI2K series are static constant current generators for very stable alternating currents over a wide load range. Depending on the version, the series covers output currents from 50 A to 20 kA and powers from 600 VA to 300 kVA. The devices operate with an adjustable output frequency of 40 to 200 Hz and support sinusoidal as well as freely definable (arbitrary) output forms. For higher test powers, systems can be synchronized (for polyphase applications) or connected in parallel (up to 1 MVA or 100 kA).
Call us or send us a request for quotation, we will be happy to advise you and configure the optimum system for your application together with you:
General features and possible applications
- Developed for thermal and magnetic tests on switches, fuses, relays and trip units including precise trip time measurement
- Thermal testing of contacts, cables and connections (junctions)
- Tests on transformers, coils and magnetic cores
- Testing and calibration of measuring devices
- Sequencer timer for test sequences (e. g.B. ramps, dips, loops) with a time resolution of up to 1 ms
- Multi-range systems (1 to 3 current ranges) with manual or automatic range switching
- Stable control with access to PID parameters, low harmonics and high accuracy
- PC connection and integration into automatic test lines via serial interfaces and programmable digital I/Os
Available models in the GI2K series
The GI2K series is designed as a model-dependent combination of rated power and rated current. This allows you to select the right device based on your required amperage and the required test power.
Available power levels
- 600 VA
- 1200 VA
- 2500 VA
- 5 kVA
- 7.5 kVA
- 10 kVA
- 15 kVA
- 20 kVA
- 30 kVA
- 50 kVA
- 75 kVA
- 100 kVA
- 150 kVA
- 200 kVA
- 300 kVA
Available rated currents
- 50 A
- 120 A
- 240 A
- 350 A
- 500 A
- 750 A
- 1000 A
- 2000 A
- 3000 A
- 4000 A
- 5000 A
- 6000 A
- 8000 A
- 10 kA
- 12 kA
- 15 kA
- 20 kA
- Further rated currents on request
Call us or send us a request for quotation, we will be happy to advise you and configure the optimum system for your application together with you:
Case and installation variants
- Horizontal built-in rack
- Vertical built-in rack
- Table-topRack (especially for low power)
- Rollable control cabinet (medium power)
- Control cabinet
- Electronics and power section separate for board mounting
Model options and additional options
- /M-GI-SW: Software GImanager with single-phase arbitrary function
- /M3-GI-SW: Software GImanager with three-phase arbitrary function
- /Rack: Rack for installation (up to 5 kVA)
- /Rack-V: Rack for vertical installation (up to 5 kVA)
- /3-Rack: Switch cabinet with three-phase sources
- /LAN: LAN interface
- /USB: USB interface
- /Rout: Output on the rear
- /Fout: Output on the front
- /Sout: Access to special output (specification required)
- /ATE: Without display
- /Cons: Separate operating unit (cable 3 m)
- /F-I/O: I/O and serial connections on the front
- /R-I/O: I/O and serial connections on the rear
- /F-ms: Main switch on the front
- /R-ms: Main switch on the rear
- Other versions and finishes on request
Product features of the series:
- Output current range: 50 A to 20 kA
- Output power: 600 VA to 300 kVA
- Output frequency: 40 to 200 Hz (resolution 0.01 Hz, accuracy 0.15%)
- Bandwidth: > 500 Hz
- Waveforms: sinusoidal or freely definable (arbitrary)
- Number of current ranges (scales): 1 to 3, manually or automatically switchable
- Current resolution: 0.3% of final value (F.S.)
- Min. adjustable current: 1/20 of final value (F.S.)
- Accuracy (current): better than 0.3% F.S.; current measurement: range +10% F.S., resolution 0.2%, accuracy 0.3%
- Voltage measurement: range +10% F.S., resolution 0.5%, accuracy 0.5%
- Additional measurements: Power factor (PF), impedance, frequency; display includes current, time, load voltage, active power/reactive power, load impedance
- Harmonic distortion (THD) at 50-60 Hz: typ. 0.2%; ripple HF: typ. 0.3% F.S.
- Sequencer timer: 1 ms to infinity, resolution 1 ms, up to 30 steps; modes incl.auto-repeat, ramp, pause/resume, continuous or pulsed
- Synchronization/phase shift: auto/mains/external; 0-360°, resolution 1°, accuracy ±1°; start angle 0-360°
- Interfaces: RS232 and RS485 (isolated); optional USB, LAN or fiber optics
- Digital I/Os: 4 inputs (24 V NPN, programmable) and 4 outputs (24 V PNP, programmable)
- Booster/analog control: 0 to 20 pk-pk (use as power amplifier possible)
- Supply: 230 V 1~ ±10% or 400 V 3~ ±10%, 45-65 Hz; cos(phi) typ. 0.85; protection via automatic
- Isolated output; insulation line/output/GND: 2500 Vrms, output/GND: 1500 Vrms
- Cooling: forced ventilation; degree of protection IP20; operating temperature 5-40 °C, storage -5 to 60 °C
- Noise level: typ. 65 dBA (at 1 m)
- Safety/EMC: CE (EMC and LVDT)
Call us or send us a request for quotation, we will be happy to advise you and configure the optimum system for your application together with you: